Jandy lxi air flow fault If your heat pump is not operating use the following troubleshooting guide to resolve pool heat pump issues. Been in my house for about 5 years - pool and equipment came with the house, and was clearly a few years old at that point. The conductors on the load side of the ground-fault circuit-interrupter shall not occupy conduit, boxes, or enclosures containing other conductors unless the additional conductors are also protected by a ground-fault circuit Consult the Jandy technical support department or your local Jandy dealer with any questions or problems involving your Jandy equipment. My pump basket and skimmer basket are both clean so not sure what the next thing to check for is. Read these installation and operation instruc-tions completely before proceeding with the installa-tion. We've tried using compressed air to clean out any dirt or debris but nothing helps. But, when I test the voltage between (A) and F2 coming from the power distribution board, I get 120V (same for F1). Jun 23, 2023 · Ignition problems are also common with Jandy JXi pool heaters. Check the air hose from the fan to the Air Pressure Switch for holes and kinks. Pool novice here with a Jandy LXi - getting IGN FAULT on display and the heat won't turn on. ) when heater is turned on, the FENWAL shows a single flash light which indicates an air flow fault. Either the switch switch has a bad connection on the wire connecting it with the Fenwal, or the switch is bad (very unlikely), or the small sensing hoses are obstructed/cracked. I go to fire it up (booster pump is running already of course) and nothing happens. I have had numerous service calls under warranty. Error Message - AIR FLOW SW Measure voltage between Ground and terminal 7 of the Safety Switch connection to the GUI. There are several reasons that a pool heater will not light. Do not use it as a heating boiler or general service water heater or to heat salt water. Workbook JXi Pool&Spa Heater is a training manual for pool repairmen. Please note that these LED codes and their corresponding fault descriptions are based on the information provided in the JANDY LXi heater manual. The spa functions perfectly otherwise, with air, bubbles, etc. I checked the obvious signs like blockage (inlet and outlet) of the airflow I am relatively new to pool ownership, and I have a Jandy heater that has a fault that says 'Check flow'. Let us know if you find this video helpful and if you'd like to see more videos like Check for down draft, soot, and/or low gas pressure. Mar 1, 2008 · Many times the squirrel cage on the motor rusts out and thus doesn't provide the air flow for the air switch. Someone Jandy Lxi Pool Heater Fault Check Ign Control If you have a Jandy Lxi pool heater, it is important to do regular fault checks. I have a flow chart for fault codes too. Refer to the Jandy JXi pool heater manual for fault check ignition steps. DIYin' it with Laughing Moms! Today we fix the air flow problem on our Jandy LT400N-L Pool Heater. Follow step-by-step guides and videos to fix the problem and get your pool heater up and running smoothly. If the resistance falls below a certain threshold, then it indicates that there is water present and triggers an alert. Fluctuating Filter Pump Pressure Fluctuating filter pump pressure can cause the pump to burn out, lower water flow, and filter pressure problems. In order for the sensor to work properly, it must be installed Aug 19, 2018 · I followed the LXI Troubleshooting Guide all the way to step 12 (Check Blower). to/3prttIR Let's Make The Trades Great Again & While Oct 31, 2024 · Is your Jandy pool heater not working correctly? Before calling a professional, try resetting it yourself in just 3 simple steps! 24 VAC between Red (2) wire and Yellow (1) wire on Transformer? Discover expert answers about the air flow fault light on ignition modules. I was just getting ready to run through the jandy troubleshooting flow chart, which looked pretty complicated, and seems to mostly tell people to replace their blower, or call a service guy, when I found an old TFP post. The last service call under warranty, the technician called me and said it was working fine. The Jandy Fault Shorted H20 Sensor is a device used to detect the presence of water in a swimming pool or hot tub. 1 Introduction ns for the Zodiac Jandy LXi pool and spa heaters. YES For Ignitor Test, remove common probe from blue(2) wire. Feb 18, 2011 · My Jandy LXi heater seems to not be working. We can smell gas from the unit trying to click in but no heat. However, like any other appliance, they can also encounter problems that affect their performance. Read these installation and operation instruc-tions co pletely before proceeding with the installa-tion. Apr 29, 2017 · My Jandy Lxi power distribution card got wet and burnt up. Gently blow into the tube connected to the Air Flow Switch and check with an ohmmeter if the switch electrically closes. Do not use the heater to maintain pool or spa water temperature below 70°F. If your heater is not igniting, it could be due to a fault in the ignition system. The most common cause is a fuel delivery issue. , for water flow problems. No flow issues can also occur with Jandy JXi pool heaters. Consult your dealer for the appropriate Jandy products Jandy Pool Heater FAULT CHECK IGN STEPS Ignition Failure & How to Prevent Premature Retirement Jandy JXI400 Issues! Bad Pool Temperature Reading! Bad Control Board Diagnosed and Replaced! I have a Jandy LXI pool heater, I'm getting a fault check IGN control after about 3 minutes of trying to ignite. It says Remote TSTAT enabled, which I believe is for my Jandy remote. Oct 27, 2020 · Now, I am receiving a Fault - Check IGN Control error with my Jandy LXI pool heater, so we are unable to heat the pool or spa. Apr 16, 2022 · The Fenwal is not detecting air flow after the blower is energized. A ground-fault circuit-interrupter must be provided if this device is used to control underwater lighting fixtures. STEP 6 - Check Pressure Switch 24 VAC at black wire of Pressure Switch? NO Perform Back Pressure Test. Perform steps in the order given. 5 PSI or more, replace Pressure Switch. I keep turning the breaker off to reset it and most of the time I get an Air Flow fault, but sometimes the Pressure fault lights up instead. If less, check pump, filter, etc. Consult the Zodiac factory, or local factory repre-senta ive, with any questions regarding this equipment. If all of that checks out, then the air switch would be the next thing to check. When I turn it on the fan starts up, after 10-15 seconds there is a click and the gas turns on (can smell it), a couple of seconds after that it lights and produces strong heat for about 5 seconds and then the heat stops. Shouldn't F2 from the PDB be 0? Does this suggest a bad/shorted blower/capacitor or Jandy pool heaters are known for their reliability and efficiency in heating swimming pools. He just. Is 24 VAC present? Yes Jandy JXI series gas pool heater - FAULT CHECK IGN STEPS explained in this Step-by-Step Instructional Video. If the fan never switches to high speed replace the Ignition Control. It looks like it normally does, even lets me choose between Pool or Spa. When I check the voltage between the F2 terminal on the Ignition Control and ground (A) I get nothing (same for F1). Learn about changes to the air pressure switch, circuit board, and more! May 12, 2022 · Jandy Pool Heater Won’t Ignite [9 Easy Fixes] In this section, we will take a deeper look at the possible reasons why your Jandy pool heater won’t ignite and provide you with the simplest solutions. Apr 21, 2023 · Welcome to TFP. Make certain the fan is running. If the problem persists, it might be time to call in a professional. May 27, 2023 · Jandy LT400 Heater not coming on at all - Air Flow fault Postby damagd » Sat 27 May, 2023 07:57 My heater will not come on at all. The most common causes of the ignition fault are a faulty igniter, a clogged burner orifice, or Feb 24, 2013 · Was it Jandy JXi/LXi Power Distribution PCB Kit | R0458100 or Jandy LXi Controller Power Interface Circuit Board R0458200? Do you have 24V between the "gnd" and "24VAC" terminals on the fenwal? Refer to the wiring diagram on page 24 and parts list on pages 50 & 51. I have a Jandy LXi series natural gas heater, which up until today worked just fine. Consult the Zodiac factory, or local factory repre-sentative, with any questions regarding this equipment. If you encounter any of these LED codes, it is advisable to seek professional help to diagnose and resolve the issue. This manual must only be used by a qualified heating installer / service technician. Failure to comply could result in severe personal injury, death, or substantial property damage. This includes checking the Ignition Control (IC), which is responsible for supplying power to the igniter and gas valve when commanded by the control board. Is 24 VAC present? Yes May 21, 2020 · Hi I just tried the heater first time this season - CT location. Gas-Fired Pool and Spa Heater, Natural Gas and LP. AIR FLOW SW - Insufficient vacuum to close the air pressure switch. Jandi LXi400. Certain sections of this manual are specific to either United States o Jun 9, 2020 · Greetings pool gurus, Hoping to get some clues as to what's up with an older Jandy LXi heater that's not working consistently. I replaced the card and then got a single flash error, air flow fault, on the ignition control box. It works by detecting the electrical resistance between two electrodes when submerged in water. Read all instructions, including this manual and the Installation and Operation Manual, before installing. We had not used the heater in about 2 months, and when we fired it up Feb 20, 2016 · I don't have an LXi flow chart, only an LX, hope it helps. In addition, the gas pressure would have to be measured with a manometer to ensure it is within the operating pressures specified in the installation manual. The red Contractor's Assistant chat Customer: I have a pool heater, and I'm receiving a fault check on the ignition control after approximately three minutes of attempting to ignite. Inspection Camera: https://amzn. Troubleshooting guide for Jandy pool heaters. 1. LXi swimming pool heater pdf manual download. View and Download Jandy LXi installation and operation manual online. After a minute or so, it Feb 16, 2021 · I am trying to troubleshoot an issue with my Jandy lxi 400 heater (it is 6 years old and suddenly stopped working. Heater fires up 3 times for about 15 sec each and then shuts down with Nov 24, 2017 · My Jandy LXI 400 heater has been quite cantankerous from the beginning. I would say since its installation it may have worked 25% of the time. AGS - Automatic Gas Shutdown simply means the Ignition Control did not sense flame rectification. Check for block in flue and/or vent. An experienced technical support staff is ready to assist you in assuring the proper performance and application of Jandy products. Feb 7, 2024 · Learn how to troubleshoot common issues such as ignition failure, heater not turning on, or a “Check Flow” fault. Heater outdoors, but in a covered area so it's Jul 21, 2013 · Jandy provides for this specific condition, a salt temp sensor at over twice the cost of a regular one. May 17, 2013 · It is a Jandy LXi 400 NG The pump is running well so there should be good water flow. After the unit shuts down after seems like 3 cycles, the display indicates Fault- Check IGN Control. Page 2 Let me know if it is giving you a fault code. Reset Exhaust Temp Limit. One such problem is the ignition fault, which occurs when the heater fails to ignite and produce heat. 1 Introduction This manual provides installation and operation instructions for the Zodiac Jandy LXi pool and spa heaters. The LXi heater is specifi cally designed for heat-ing fresh water swimming pools and spas, and with proper installation and care, they will provide years of reliable service. If 2. Oct 11, 2010 · Hi Guys, I stumbled upon this site with a google search, and I'm hoping someone can help me narrow down my problem (or confirm my assessment). BTW, if you have a salt system, the temp sensor may have failed due to the salt water. ydvg ylbvr 770ox dipc1u rlhg rwiqjb9w9 c3pa3l haa865k 0vwj7d gmrnr